Multi-channel diagnostic-quality ECG acquisition ASIC for AED applications

The low-power low-noise ASIC includes 3 differential bio-potential channels and one bio-impedance measurement channel to measure body impedance variation due to respiration. Fully configurable digital filtering and processing blocks and lead-off check and pacemaker detection blocks are also embedded in the ASIC, together with right leg driver, shield driver and Wilson common terminal blocks, making […]
Automotive Hall-sensor output driver for wide-range loading-conditions

The output driver includes a D/A converter, an output buffer, open-circuit detection circuits and bi-directional data transfer circuits. The main challenges in this development were accuracy and settling requirements in combination with the wide range of capacitive loading and leakage at high temperatures. FEATURES 12 bit resolution / 13 bit accuracy Load resistor/load capacitor: >5kΩ/330pF […]
Medical patch highly accurate timer ASIC for patient medication reminder

The battery operated ASIC is the main part of a new generation wearable electronic reminder system for timely medication intake, producing mild electronic pulses to the patient. It contains a highly accurate fully integrated on-chip clock, a power generation block consisting of a DC-DC converter and a high-voltage driver, and a programming unit to program […]
128-channel MEMS speaker driver with 1.8V to 90V DC-DC

This ASIC drives a digital MEMS speaker which produces sound by moving 1024 pixels. The High-voltage driver ASIC main goal is to generate the high voltage supply levels and to drive the individual rows and columns of the MEMS device. The ASIC is co-packaged together with the 8mmx8mm MEMS element and protected by a coating […]
Electrode arrays for nerve stimulation in cochlear implants

ICsense has implemented direct nerve stimulation electrode arrays and nerve response telemetry for cochlear implants. The key challenge was to deliver an accurate charge to the tissue and be able to measure identical charges from the tissue. As the electronics are wirelessly powered, low power consumption is crucial. The response of the nerves and brain […]
40-channel DBS brain stimulation and recording ASIC

The ASIC is part of a novel DBS system with at least 40 electrodes for steering brain stimulation and brain recording. The ASIC is close to the electrodes, not part of the IPG/INS. For safety, AC power is transferred to the ASIC through a dedicated DC-AC-DC conversion scheme over the lead cable together with the […]
High-memory passive EPC Gen 2 RFID tags

In cooperation with Tego Inc. and Easics, a high-memory EPC RFID Class-1 Generation-2 UHF RFID compliant passive RFID tag is developed. This tag was selected by Airbus to perform maintenance management on their newest airplanes. The extended non-volatile memory of 32kbytes exceeds standard commercial tags (512 bits) and the interface capabilities are unrivalled. Moreover, the memory […]